Testing a Sample Before You Commit: How Buyers Verify Pakistani Ore in Their Own Lab
Yes, you can test a sample in your own lab before you commit. That's standard practice when buying crushed ore from Pakistan, and any serious supplier should expect it. At GBX Resources each lot is sampled and analysed by SGS Pakistan and sold against that SGS certificate — but buyers are welcome to pull their own sample and run it in their lab, and to appoint SGS or their own inspector at loading.
So here's how to do it properly, and what to watch for.
Why test a sample at all when there's an SGS certificate
Because an independent number on paper and a number you generate yourself are two different kinds of confidence. The SGS certificate tells you what an accredited third party found. Your own assay tells you what your lab finds — on your equipment, with your method. When both line up, you buy with a clear head.
Ore isn't uniform. It's crushed rock from a concession, not a refined product, so grade varies across a lot. That's exactly why sampling method matters more than the single headline figure. A good result from a badly taken sample means nothing.
Honestly, the buyers who get burned usually aren't the ones who tested too little. They're the ones who tested a sample that didn't represent the actual lot they were paying for.
If you want the general background on how these ores are sold, the minerals overview page lays out the format — crushed ore, sold against SGS analysis, FOB Karachi or CFR on request.
How to get a representative sample for your lab
This is the part people rush. Don't.
A sample is only useful if it reflects the whole lot. For crushed ore that means a composite pulled from many increments across the material, then reduced down (riffle splitting or coning and quartering) to the small amount your lab actually needs. One handful off the top of a bag isn't a sample. It's a guess.
A clean chain of custody from pile to lab:
- Agree who takes the sample — SGS, your own appointed inspector, or a split prepared at loading
- Take increments from multiple points, not one spot
- Split into at least three parts: one for the seller, one for the buyer, one sealed as a referee
- Seal and label each part with the lot reference
- Record the crush size the sample was taken at
That referee (umpire) sample is the one that settles arguments. If your result and the SGS result drift apart, an agreed third lab tests the sealed referee portion and that number stands. Set that rule before loading, not after.
Matching your lab method to the certificate
Two honest labs can report different numbers on the same ore. Not because someone's wrong — because they used different methods or prepared the sample differently.
A few things that move the result:
- Method. Titration, ICP, XRF and fire assay don't always agree to the last decimal. Antimony by titration vs XRF, for example, can read differently.
- Moisture basis. Dry basis vs as-received changes the grade. Pin down which basis the certificate uses and run yours the same way.
- Particle size and homogenisation. If your lab doesn't pulverise and mix the sub-sample properly, you get scatter.
- Element suite. Make sure you test the payable element and the penalty elements, not just the headline grade.
For mineral sample analysis to actually be useful, tell your lab the method on the SGS certificate and ask them to mirror it. Then a gap between the two numbers means something real — not just two different recipes.
What's a reasonable gap? That depends on the element and the method, and it's something you and the seller should agree in writing. I won't throw out a percentage here because the acceptable tolerance varies by mineral and lab. Set it in the contract.
What to request from the supplier before you test
Ask for these up front. It saves a round of emails later.
| Request | Why it matters |
|---|---|
| SGS certificate of analysis for the lot | Your baseline to compare against |
| Crush size / size range | Your lab prep should match the material |
| A representative sample (or split at loading) | So you test what you'll actually ship |
| The method SGS used | So you can mirror it |
| Moisture basis on the certificate | Dry vs as-received changes the number |
| Agreement on referee lab and tolerance | Settles any dispute cleanly |
For the specific ores, the detail lives on each page — antimony ore, lead ore with silver, and copper ore. Each lot is sold against its own SGS certificate, so the sample you test should be tied to the lot you're quoting on.
Testing nephrite jade is a different job
Jade doesn't go to an assay lab. You're not checking grade — you're checking the stone.
Rough nephrite jade is sold as rough blocks by weight, and each block is weighed, photographed and filmed. So your "verification" is visual and physical: colour, translucency, texture, cracks, the ratio of usable material to waste. A carver or wholesaler judges that from the weight, the photos and the film, and from inspecting blocks in person or through an appointed inspector at loading.
If you buy jade on grade figures, something's off. There are none to publish. You buy it on what the stone actually is.
Common mistakes that waste everyone's time
- Testing a non-representative grab sample, then blaming the seller
- Not agreeing a referee lab and tolerance before loading
- Comparing a dry-basis number against an as-received number
- Using a different method than the certificate and expecting an exact match
- Skipping the loading inspection because the paper looked fine
Look, the point of testing before you commit isn't suspicion. It's alignment. You want your number and the SGS number sitting close enough that nobody's arguing on arrival. Good sampling and a matched method get you there.
Your next step
Decide what you need to test, then ask for it in writing: the SGS certificate, the crush size, the method, and a representative sample or a split at loading. Request a quote on the matching mineral page — antimony, lead-silver, copper or nephrite — or email hello@gbxresources.org, and we'll confirm availability and how you'd like the sample handled.
Discuss a JV or off-take →